In short
- A barndominium exterior door landing calculator checks the landing outside (or inside) a door against IRC 2021 Section R311.3: width, depth, slope and how far below the threshold it sits.
- The landing is at least as wide as the door and 36 in deep, falling no more than 1/4 in per 12 in.
- Step down from the threshold: 1 1/2 in at the required egress door, 7 3/4 in outside if it swings in, and 7 3/4 in at other doors.
- Example: a 32 in door with a 42 in wide, 30 in deep landing sitting 3 in down is short on depth and on the drop.
On this page
This barndominium exterior door landing calculator is for Tyler and Smith County owners who are reading a plan for the front door, a back door or the man-door next to a shop overhead door. Say which kind of door it is, how it swings, and give the width of the door and the size of the landing. It marks each check OK or Fails against the 2021 IRC. It pairs with our guide to windows and doors, the shop door size calculator and the porch overhang depth calculator. Local rules are in the Smith County permits guide.
En español: calculadora de descanso de puerta exterior
Example: a required egress door 32 in wide that swings out, with a 42 in wide, 30 in deep landing that falls 1/2 in and sits 3 in below the threshold (an example, not a ruling for any building).
How the landing check works
- Pick the door.
The required egress door has the tightest step-down limit. The example is the main entry.
- Say how it swings.
A door that swings in leaves the outside landing free to sit lower. The example door swings out.
- Enter the door and landing sizes.
The landing is at least as wide as the door and 36 in deep. The example is 42 in wide and 30 in deep.
- Enter the fall and the drop.
Fall across the landing is limited to 1/4 in per 12 in. The example drops 3 in below the threshold against a 1 1/2 in limit.
- Take it to the plan.
Ask the builder to mark the landing size and its height below the threshold at each exterior door.
Step down from the threshold (IRC 2021 R311.3.1 and R311.3.2)
| Door | Condition | Limit |
|---|---|---|
| Required egress door, outside | Door swings over the landing | 1 1/2 in |
| Required egress door, outside | Door does not swing over it | 7 3/4 in |
| Required egress door, inside | Any | 1 1/2 in |
| Other exterior door | Any | 7 3/4 in |
Landings and floors are measured from the top of the threshold down. The outside 7 3/4 in exception at the egress door applies only when the door does not swing over the landing or floor. Where the outside landing is not at grade, a stairway (R311.7) or ramp (R311.8) must reach grade.
Landing basics (IRC 2021 R311.3)
| Item | The code asks for | Section |
|---|---|---|
| Landing width | Not less than the door served | R311.3 |
| Landing depth | 36 in or more in the direction of travel | R311.3 |
| Slope | 1/4 in per 12 in at most (2 percent) | R311.3 |
| Egress door size | 32 in clear width, 78 in clear height | R311.2 |
| Storm or screen door | May swing over steps and landings | R311.3.3 |
An exterior balcony under 60 sq ft that is reached only from a door may have a landing shallower than 36 in. The 32 in and 78 in figures in R311.2 apply to the required egress door only; other doors need not meet them.
Where landing plans go wrong
- A stoop that is too shallow. A 30 in deep landing is short of the 36 in minimum, even when it looks like enough room to stand.
- Pouring the slab level with the floor. A slab poured flush with the top of the threshold is fine; a landing 3 in down at an outswing egress door is not.
- A landing narrower than the door. A 36 in door needs a landing at least 36 in wide, so a narrow stoop can fail.
- Too much fall. A landing sloped for drainage may fall at most 1/4 in per 12 in; more makes a ramp.
- Forgetting the inside. The floor inside each exterior door counts as a landing too, as wide as the door and 36 in deep.
What to ask your builder
- How far below the threshold is each landing? Ask for the figure at every exterior door, outside and inside.
- Which door is the required egress door? It carries the 1 1/2 in limit unless the door swings in.
- How do the doors swing? An outswing door changes the step-down limit outside.
- What is outside a shop man-door? Two or fewer steps may need no landing if the door swings in; more steps need a landing.
- Who is licensed? Read how to choose a barndominium builder.
Next step: get a written quote
This tool finds code items to ask about, not a design or a price. We are a referral service, not a contractor; we connect visitors with independent local providers. Use the form below to ask independent barndominium builders near Tyler for a written quote that states the landing size and the step down at each exterior door, and read how to choose a barndominium builder first.
Sources
- 2021 International Residential Code, Chapter 3 (Texas edition on UpCodes): Section R311.2 egress door, R311.3 floors and landings at exterior doors, R311.3.1 floor elevations at the required egress doors, R311.3.2 floor elevations at other exterior doors, R311.3.3 storm and screen doors, R311.7 stairways and R311.8 ramps.
- Which code edition and inspections apply to a lot depends on the city or county; see our Smith County permits guide and confirm with the builder and the building official.
Frequently asked questions
How deep must the landing outside an exterior door be?
Section R311.3 of the 2021 IRC asks for a landing or floor on each side of each exterior door, as wide as the door and not less than 36 in in the direction of travel. A small exception lets an exterior balcony under 60 square feet that is reached only from a door have a landing shallower than 36 in.
How far below the threshold can the landing be?
At the required egress door, R311.3.1 says the landing or floor may be no more than 1 1/2 in lower than the top of the threshold. The exterior side may be as much as 7 3/4 in below it if the door does not swing over the landing or floor. Other exterior doors (R311.3.2) may have a landing up to 7 3/4 in below the threshold.
Does a door with two or fewer steps outside need a landing?
For doors other than the required egress door, R311.3.2 says a top landing is not required where a stairway of not more than two risers is on the exterior side, provided the door does not swing over the stairway. The required egress door has no such exception, and steps outside it follow the stairway rules of R311.7.
How much slope can an exterior landing have?
R311.3 limits the slope at exterior landings to 1/4 unit vertical in 12 units horizontal, which is 2 percent. That is enough fall to shed water and still feel level. A 36 in deep landing may fall at most 3/4 in from the door to the edge.
Can a storm or screen door swing over the steps?
Yes. R311.3.3 says storm and screen doors are permitted to swing over exterior stairs and landings. It does not apply to the main door behind them.