Tyler BarndominiumsGet free quotes

Barndominium Footing Width Calculator: Wall Footing Size by Soil and Stories (Tyler, TX)

For a 2 story slab-on-grade barndominium 40 ft wide on 1,500 psf clay, IRC 2021 Table R403.1(1) gives 13 x 6 in. for a 32 ft wide building and the code adds width and thickness above 32 ft, so the wall footing is at least 17 in. wide by 8 in. thick. Ask your builder or engineer which footing size is on the foundation drawing.

In short

  • A barndominium footing width calculator reads the minimum wall footing width and thickness from IRC 2021 Table R403.1(1) for your soil bearing value, stories and foundation type, then adds the code adjustment for building width.
  • The answer is a code minimum to compare with the drawing, not a foundation design. An engineer or the kit supplier sets the real footing.
  • Example: 2 story slab, 1,500 psf clay, 40 ft wide: 17 x 8 in. (table 13 x 6 in. plus the width adjustment).
On this page
  1. How the footing size is found
  2. Table R403.1(1) footings for 20 psf roof live load (width x thickness, in.)
  3. How building width changes the footing
  4. Where footing sizing goes wrong
  5. What to ask your builder or engineer
  6. Next step: get a written quote
  7. Sources
  8. Frequently asked questions

This barndominium footing width calculator is for Tyler and Smith County owners who want to know how wide and thick the concrete under the walls has to be before the crew digs. Pick the soil, the floors and the foundation type, and enter the building width. It pairs with our post footing size calculator (pads under posts), our slab rebar calculator and our slab concrete calculator. East Texas clay is covered in our clay soil foundation guide; local rules are in the Smith County permits guide.

En español: calculadora de ancho de zapata corrida

1. Soil and building

1,500 psf is the code default for clay and silt (Table R401.4.1). Choose a higher value only if a soils report supports it.

Optional. Overrides the choice above. Between table columns the code allows straight-line interpolation.

The 40 here is an example, not your width. Use the dimension perpendicular to the footing you are sizing, usually the short side.

Footing17 x 8 inwide x thick, 40 ft building
Table value13 x 6 in2 story slab, 32 ft wide
Width added+4 in+2 in thick for 40 ft
Soil1,500 psfcode default, clay and silt

Example: a 2 story slab-on-grade home 40 ft wide on 1,500 psf soil (an example, not a ruling for any lot).

How the footing size is found

  1. Pick the soil value.

    Use 1,500 psf for clay or silt unless a soils report says otherwise. Better soil never makes the footing narrower than 12 in. wide by 6 in. thick.

  2. Find the row.

    Table R403.1(1) has a row for each count of stories and foundation type: slab-on-grade, crawl space or basement. The example is a 2 story slab.

  3. Read the column.

    At 1,500 psf the 2 story slab row says 13 x 6 in. At 2,000 psf and above it drops to 12 x 6 in.

  4. Adjust for width.

    The table is for a 32 ft wide building. Each full or partial 4 ft over 32 ft adds 2 in. of width and 1 in. of thickness. A 40 ft building adds 2 steps: +4 in. and +2 in.

  5. Take it to the drawing.

    Ask which footing size the foundation drawing shows and why it is larger or smaller than this minimum.

Table R403.1(1) footings for 20 psf roof live load (width x thickness, in.)

Floors and type1,500 psf2,000 psf2,500 psf
1 story, slab12 x 612 x 612 x 6
1 story, crawl space12 x 612 x 612 x 6
1 story, basement16 x 612 x 612 x 6
2 story, slab13 x 612 x 612 x 6
2 story, crawl space15 x 612 x 612 x 6
2 story, basement19 x 614 x 612 x 6

Light-frame walls, 32 ft wide building, clear-span roof. The Texas roof live load is 20 psf, so the 20 psf block of the table applies. All values are in inches, width first. From 3,000 psf up, every row of the table is 12 x 6 in.

How building width changes the footing

Building width (ft)Width change (in.)Thickness change (in.)
24−4−2
3200
36+2+1
40+4+2
48+8+4
60+14+7

Added to the table value for each 4 ft over 32 ft (a partial 4 ft counts as a full step: our reading). Narrower buildings may reduce by the same steps but never below 12 x 6 in.

Where footing sizing goes wrong

  • Using the 32 ft table for a 40 ft barn. The printed values are for 32 ft. Wider buildings add width and thickness.
  • Treating the table as a post-frame or metal-building design. Those systems carry load at columns and come with an engineered foundation. Follow their drawing.
  • Forgetting veneer. Brick or stone veneer on the wall uses Table R403.1(2), which is wider. Tell the builder if you plan masonry wainscot or veneer.
  • Confusing thickness with depth. The thickness is the concrete height. Exterior footings must also sit at least 12 in. below undisturbed ground (R403.1.4), more where frost or soil movement requires.
  • Assuming good soil because the lot looks firm. East Texas clay can shrink and swell. Ask whether a soils report was done.

What to ask your builder or engineer

  • What soil bearing value was used, and is there a soils report? A number with no report is an assumption.
  • What footing width and thickness are on the drawing, and which load case sets them? Compare with the code minimum here.
  • Is this a stick-frame, post-frame or steel-frame foundation? The engineered drawing controls over this table.
  • When is the footing inspected? Ask the building official about the footing inspection before concrete. See our Smith County permits guide.
  • Who is licensed? Read how to choose a barndominium builder.

Next step: get a written quote

This tool finds a code minimum to ask about, not a design or a price. We are a referral service, not a contractor; we connect visitors with independent local providers. Use the form below to ask independent barndominium builders near Tyler for a written quote that states the footing width, thickness, soil value used and who stamps the foundation drawing, and read how to choose a barndominium builder first.

Sources

Frequently asked questions

What is a barndominium footing width calculator?

It reads the minimum width and thickness of a continuous concrete wall footing from IRC 2021 Table R403.1(1) for the soil bearing value, the number of stories and the foundation type, then applies the code's adjustment for building width. It sizes the footing under walls. It does not size post footings, slab thickness or rebar; our other calculators do that.

What soil bearing value should I use?

Table R401.4.1 lists 1,500 psf as the presumptive value for clay, silty clay and silt, which covers much of East Texas, and 2,000 psf for sand and silty or clayey sand. If a soils report gives an allowable bearing value, enter that instead. A value below 1,500 psf is outside the table and needs an engineer.

Why does a 40 ft wide building need a wider footing?

The table assumes a building 32 ft wide with a clear-span roof. For every 4 ft of building width over 32 ft the code adds 2 in. to the footing width and 1 in. to its thickness. Barndominiums are often 40 ft wide or more, so they usually land above the printed table value.

Does this apply to a metal building or post-frame kit?

Not directly. Table R403.1(1) is for light-frame walls on continuous footings. Steel-frame and post-frame kits come with an engineered foundation drawing, and that drawing controls. Use this page to understand and question the numbers, not to replace the drawing.

Get free quotes from barndominium builders near Tyler

Takes about a minute. Free, no obligation.

We share your request only with providers relevant to your job.

Get free quotes