Barndominium Post Footing Size Calculator: Pad Diameter per Post (Tyler, TX)

A 48 ft by 36 ft clear-span building on 8 ft bays has 14 wall posts, each with a 144 sq ft tributary area and about 4,192 lb of load. On 1,500 psf soil that needs a 24 in round pad, about 2.1 cu ft of concrete each at 8 in thick.

In short

  • A barndominium post footing size calculator starts from the tributary area of each post: bay spacing times half the building width in a clear-span building.
  • Load per post is that area times the roof dead load plus the roof live (or snow) load. Divide by soil bearing to get pad area; IRC Table R401.4.1 gives 1,500 psf for clay and silt.
  • Smith County is mostly clay-bearing soil, so 1,500 psf is the default here unless a soil test says otherwise. Wind uplift and post embedment are separate checks.
  • The example: a 48 ft by 36 ft building on 8 ft bays puts about 4,192 lb on each wall post and needs a 24 in round pad.
On this page
  1. How the pad size is worked out
  2. Load per post and the pad it needs
  3. Where post footings go wrong
  4. What to ask your builder
  5. Next step: get a written quote
  6. Sources
  7. Frequently asked questions

This barndominium post footing size calculator is for Tyler and Smith County owners planning a post-frame (pole barn style) barndominium who want to know how big a footing pad to expect under each post, how many posts there are, and how much concrete the pads take. Enter the building size and bay spacing, pick the soil, and it gives the load per post and the minimum round pad. It sits beside our slab concrete calculator and the foundation on East Texas clay guide.

En español: calculadora de zapatas para postes

1. The building

Post spacing is the distance from one post to the next (the bay). Barndominium wall posts are often set several feet apart; use the spacing on your plans.

2. Roof and layout

Roof live load comes from IRC Table R301.6: 20 psf for low-pitch roofs and tributary areas up to 200 sq ft, less above that. If you enter a snow load from the plans, the larger of the two is used. Dead loads are our planning figures: use the engineer's.

3. Soil and pad

Use 1,500 psf unless a soil test says otherwise. Higher rows need a soil report or the building official's approval. Pad thickness is set by the engineer; it changes concrete volume, not the bearing area.

Posts147 per wall, 8 ft bays
Tributary area144 sq ft8 ft x half of 36 ft
Load per post4,192 lbroof plus wall weight
Pad24 inround, at 1,500 psf

Example: a 48 ft by 36 ft clear-span building, 8 ft bays, 14 ft walls, 6 psf roof dead load, low-pitch roof, 1,500 psf soil and 8 in pads.

How the pad size is worked out

  1. Find the tributary area.

    Bay spacing x half the building width. Example: 8 x 18 = 144 sq ft per wall post.

  2. Add the loads.

    Roof dead load plus the larger of roof live load (R301.6) and snow. Example: 144 x (6 + 20) = 3,744 lb.

  3. Add the wall weight.

    Our planning assumption is 4 psf of wall height times the bay. Example: 8 x 14 x 4 = 448 lb, total 4,192 lb.

  4. Divide by soil pressure.

    Area = load / bearing. Example: 4,192 / 1,500 = 2.79 sq ft (402 sq in).

  5. Turn area into a diameter.

    Diameter = square root of (4 x area / pi), rounded up to the next even inch. Example: 22.6 in rounds to 24 in. Concrete = pad area x thickness.

Load per post and the pad it needs

Load on post1,500 psf2,000 psf3,000 psf
2,000 lb16 in14 in12 in
4,000 lb24 in20 in16 in
6,000 lb28 in24 in20 in
8,000 lb32 in28 in24 in

Minimum round pad diameter, rounded up to the next even inch, never under 12 in (our assumption: smaller pads are hard to place). Your own loads go in the calculator.

Building a porch or deck on those posts? Check the framing with our barndominium deck joist span calculator.

Where post footings go wrong

  • Guessing the soil. Clay and silt can be at or below 1,500 psf, and expansive clay needs a design from the engineer. See the foundation guide.
  • Sizing for the roof only. Walls, doors, a loft or a heavy ceiling add load. Tell the designer about everything the posts carry.
  • Forgetting uplift. Wind pulls on a light roof. Embedment, collars and cleats handle that, not the pad size alone.
  • Equal pads under unequal posts. A center row carries about twice a wall post here. Corner posts carry less.
  • Not matching the slab plan. If the shop has a slab, the pads, posts and slab all appear on one set of drawings. See the slab calculator.

What to ask your builder

  • Who stamped the footing design? An engineer's drawings govern the pad size, thickness and embedment. Ask for them in writing.
  • What soil value was used? Ask whether it is 1,500 psf by default or from a soil report.
  • How are posts held down? Ask about uplift, embedment depth and collar or cleat details.
  • What does the building department require? Ask which IRC edition applies. See permits in Smith County.

Next step: get a written quote

This tool sizes post footing pads, not the building or the price. We are a referral service, not a contractor; we connect visitors with independent local providers. Use the form below to ask independent barndominium builders near Tyler for a written quote that names the footing size, thickness and soil value, and read how to choose a barndominium builder first.

Sources

  • IRC 2021 R401.4.1 and Table R401.4.1: Presumptive load-bearing values (1,500 psf for clay and silt) and the soils-investigation rule below 1,500 psf; R403.1 sizes footings under piers and columns from tributary load and allowable soil pressure.
  • IRC 2021 Table R301.6: Minimum roof live loads by roof slope and tributary area.
  • National Frame Building Association (NFBA): Post-frame design guidance: post and pier footings are sized from the design force divided by allowable soil bearing, with separate checks for uplift and embedment.

Frequently asked questions

How big should a footing be for a post-frame barndominium?

The footing area is the load on the post divided by the allowable soil pressure. The IRC (R403.1) sizes footings under piers and columns from the tributary load and the soil pressure in Table R401.4.1, which is 1,500 pounds per square foot for clay and silt, the common default in East Texas when no soil test exists. This calculator does that arithmetic and turns the area into a round pad diameter. The engineer's drawings set the real size.

What is tributary area for a post?

It is the roof area a post carries: the bay spacing (distance to the next post) times the width of roof that drains to it. In a clear-span building with posts only on the two long walls, each wall post carries half the building width, so tributary area is bay spacing times half the width.

What soil bearing value should I use in Tyler?

Table R401.4.1 lists 1,500 psf for clay, silty clay, clayey silt and silt, and our default is 1,500 psf unless a soil test says otherwise. The code adds that where soils below 1,500 psf are likely, a soils investigation sets the value. Pick a higher row only when a geotechnical report or the building official supports it.

Does this size the footing for wind uplift?

No. Post-frame buildings are often governed by wind uplift and sideways loads, and the post embedment, concrete collar or cleat details handle those. This tool checks downward bearing only. Ask the building manufacturer or engineer for uplift and embedment on the plans.

Can I use a smaller pad than the calculator shows?

Not without an engineer's sign-off. The result is a minimum for the loads and soil you entered, using planning loads for the roof and walls. Posts at the building ends and corners carry less, but this tool applies the full-bay load to every post so the number errs on the safe side.

Does the calculator give a price?

No. It gives loads, diameters and concrete volumes only, with no prices. Ask for written quotes that name the pad size, thickness, and the soil value used.