In short
- A barndominium roof uplift connection calculator turns your wind speed, exposure, roof span and rafter or truss spacing into the pounds of uplift each tie must resist (IRC 2021 Table R802.11, allowable-stress loads).
- The answer is a number to ask for, not a product: "a connector rated for at least X lb of uplift." It is a planning figure; the designer and the building official decide.
- Example: 28 ft span, 24 in spacing, Exposure C, 5:12 or steeper, 120 mph: 416 lb near corners, 312 lb elsewhere.
On this page
- How the uplift check works
- Uplift per connection by wind speed (24 in spacing, 28 ft span, 5:12 or steeper)
- Spacing and span change the load (Exposure C, 120 mph, 5:12 or steeper)
- What lowers the table value
- Where uplift connections go wrong
- What to ask your builder
- Next step: get a written quote
- Sources
- Frequently asked questions
This barndominium roof uplift connection calculator is for Tyler and Smith County owners whose roof is framed with wood rafters or trusses and who want to know what rating to ask for on the hurricane ties. Choose the wind speed your building official gives you, the exposure, span, spacing and pitch; it returns the required uplift per connection in pounds. It follows our rafter span calculator, which sizes the rafter itself, and sits beside our metal roof and wall panel calculator and our Smith County permits guide.
En español: calculadora de amarres del techo contra el viento
Checks
Same roof, all spacings
| Spacing | Elsewhere | Near corners |
|---|
Example: Exposure C, rafters or trusses 24 in on center, 28 ft roof span, 5:12 or steeper, gable roof, 24 in overhang, 120 mph ultimate design wind speed (an example, not a ruling for any address).
How the uplift check works
- Pick the wind and the exposure.
Table R802.11 has one block for Exposure B and one for Exposure C, with columns at 110, 115, 120, 130 and 140 mph. Exposure D uses the C block one speed higher.
- Pick span, spacing and pitch.
Each row is a roof span from 12 to 48 ft, in three spacing groups (12, 16 and 24 in). A roof of 5:12 or steeper has its own, lower column.
- Read the force and interpolate.
The code allows straight-line interpolation between spans and wind speeds. For the example, the 28 ft row at 120 mph reads 416 lb in the 5:12-or-steeper column, with no interpolation needed.
- Apply the reductions.
Connections not within 8 ft of a building corner may use 0.75 of the value; a hip roof of 5:12 or steeper may use 0.70 of it. The two reductions do not combine. 416 lb x 0.75 is 312 lb.
- Ask for a connector rated at least that.
Round up and ask for the manufacturer's allowable uplift load for the exact connector, nails and lumber, on paper.
Uplift per connection by wind speed (24 in spacing, 28 ft span, 5:12 or steeper)
| Wind speed | Exposure B | Exposure C |
|---|---|---|
| 110 mph | 138 lb | 304 lb |
| 115 mph | 176 lb | 358 lb |
| 120 mph | 218 lb | 416 lb |
| 130 mph | 306 lb | 538 lb |
| 140 mph | 400 lb | 670 lb |
Pounds per connection from IRC 2021 Table R802.11 for connections within 8 ft of a corner (no reduction). Away from corners multiply by 0.75. Speeds are ultimate design wind speeds; your building official names the one for your lot.
Spacing and span change the load (Exposure C, 120 mph, 5:12 or steeper)
| Roof span | 16 in o.c. | 24 in o.c. |
|---|---|---|
| 18 ft | 201 lb | 302 lb |
| 24 ft | 246 lb | 370 lb |
| 28 ft | 277 lb | 416 lb |
| 32 ft | 307 lb | 462 lb |
| 36 ft | 338 lb | 508 lb |
Pounds per connection before reductions. Closer spacing means each tie carries less roof, but there are more ties.
What lowers the table value
| Situation | Multiply by |
|---|---|
| Not within 8 ft of a building corner | x 0.75 |
| Hip roof, 5:12 or steeper | x 0.70 |
| Both of the above | use only one |
| Roof overhang over 24 in | not covered |
Footnote adjustments of Table R802.11. The tabulated force also assumes a roof and ceiling dead load of 15 psf and a mean roof height of 33 ft or less.
Where uplift connections go wrong
- Using the wrong wind speed. The speed comes from the adopted code and map, not from a neighbor. Ask the building official for the value on your permit.
- Asking for "hurricane ties" with no rating. Ties come in many strengths. Name the pounds, for example "rated for at least 416 lb of uplift", and ask to see the manufacturer's load table.
- Stopping at the top of the wall. The uplift has to travel down through the studs, the top plate, the wall-to-floor connection and the foundation anchors. Ask who designed that whole path.
- Applying a wood-frame table to a kit building. Post-frame and metal-building kits are designed as a system. Their drawings, not this table, give the connection loads.
- Assuming rafter size solves it. A rafter that passes the span check can still lift off the wall. See our rafter span calculator for the member itself and our post footing size calculator for the foundation end.
What to ask your builder
- What uplift rating are the roof-to-wall connectors, in pounds? Ask for the connector model and its allowable uplift load, and compare it with your number here.
- Which design wind speed and exposure are on the plans? Both should appear on the plan set and match what the building official told you. See our Smith County permits guide.
- Are the roof members trusses or rafters, and who designed the connections? Trusses come with the maker's drawings that list the uplift at each bearing. See how to choose a barndominium builder.
- Is there a continuous load path from the roof to the foundation? Ask what connects wall to floor and floor to slab, and when the framing inspection happens.
Next step: get a written quote
This tool finds a number to ask for, not a product or a price. We are a referral service, not a contractor; we connect visitors with independent local providers. Use the form below to ask independent barndominium builders near Tyler for a written quote that names the roof-to-wall connector, its uplift rating and the design wind speed, and read how to choose a barndominium builder first.
Sources
- 2021 International Residential Code, Chapter 8 (Texas edition on UpCodes): Section R802.11 roof tie uplift resistance and its two exceptions, Sections R802.11.1 and R802.11.2, and Table R802.11 rafter or truss uplift connection forces from wind (ASD), pounds per connection, with its footnotes on overhang, mean roof height, corners and hip roofs.
- Whether the 2021 IRC and which design wind speed apply to your lot depends on the city or county; see our Smith County barndominium permits guide.
Frequently asked questions
What is a roof uplift connection?
It is the metal strap, clip or tie, often called a hurricane tie, that fastens each rafter or truss to the wall below so that wind suction cannot lift the roof off. IRC 2021 Section R802.11 requires roof assemblies to resist uplift, and Table R802.11 lists the force per connection in pounds.
What wind speed should I enter for Tyler?
Do not guess. The design wind speed comes from the code edition your city or county has adopted and the wind map in the code, and it can differ between a city lot and a rural lot. Ask the building official which ultimate design wind speed applies to your address. The table behind this calculator covers 110 to 140 mph.
Does this apply to a post-frame or steel-frame barndominium?
Not directly. Table R802.11 is written for light-frame wood roofs on wood-framed walls. A post-frame or metal-building kit comes with its own engineered connections; ask the supplier for the uplift load path in the sealed drawings.
Why do the corners need more?
Wind suction is strongest at roof edges and corners. The code lets you multiply the tabulated force by 0.75 for connections that are not within 8 ft of a building corner, so the corner zone carries the full table value.
Can I skip hurricane ties if the load is low?
Section R802.11 lets rafters and trusses be attached by the nailing in Table R602.3(1) when the table force is 200 lb or less per connection, or when a short list of conditions is met (wind 115 mph or less, Exposure B, 5:12 or steeper, span 32 ft or less, spacing 24 in or less). The calculator reports which case applies, as we read it. Many builders still use ties; ask which they plan.